Voordeelbundel
Journeyman Electrician | FULL BUNDLE 2023/24
ALL EXAMS Journeyman Electrician | 2023/24 @ STUVATE -STUVIA USA
[Meer zien]ALL EXAMS Journeyman Electrician | 2023/24 @ STUVATE -STUVIA USA
[Meer zien]Journeyman Electrician Practice Test | 2023/24 
 
Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - THHN 
 
conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognize...
Voorbeeld 2 van de 8 pagina's
In winkelwagenJourneyman Electrician Practice Test | 2023/24 
 
Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - THHN 
 
conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognize...
Journeyman Electrician Exam| 50 questions and answers 
 
An electromagnet can be switched on and off - And advantage of an electromagnet over a permanent magnet is 
Scatters light uniformly in all directions - An excellent diffuser surface is one that 
In a photovoltaic cell - Light is converted ...
Voorbeeld 1 van de 3 pagina's
In winkelwagenJourneyman Electrician Exam| 50 questions and answers 
 
An electromagnet can be switched on and off - And advantage of an electromagnet over a permanent magnet is 
Scatters light uniformly in all directions - An excellent diffuser surface is one that 
In a photovoltaic cell - Light is converted ...
Journeyman Electrician Practice Test | 2023/24 
 
Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - THHN 
 
conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognize...
Voorbeeld 2 van de 8 pagina's
In winkelwagenJourneyman Electrician Practice Test | 2023/24 
 
Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - THHN 
 
conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognize...
Electrician's Licensing Exam | 229 questions and answers | with complete solution 2023/24 
 
NEC Article ______ defines breakers and fuses. - According to NEC Article 100, a device that opens and closes a circuit by nonautomatic means automatically closes for a predetermined overcurrent. 
Annex __...
Voorbeeld 2 van de 12 pagina's
In winkelwagenElectrician's Licensing Exam | 229 questions and answers | with complete solution 2023/24 
 
NEC Article ______ defines breakers and fuses. - According to NEC Article 100, a device that opens and closes a circuit by nonautomatic means automatically closes for a predetermined overcurrent. 
Annex __...
Florida Journeyman Electrician CB Exam 1 
 
An advantage of an electromagnet over a permanent magnet is that... - an electromagnet can be switched. 
An excellent diffuser surface is one that... - scatters light uniformly in all directions 
Light is converted into electricity... - in a photovoltai...
Voorbeeld 1 van de 2 pagina's
In winkelwagenFlorida Journeyman Electrician CB Exam 1 
 
An advantage of an electromagnet over a permanent magnet is that... - an electromagnet can be switched. 
An excellent diffuser surface is one that... - scatters light uniformly in all directions 
Light is converted into electricity... - in a photovoltai...
Residential Electrician Exam #1 
 
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only - A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of ot...
Voorbeeld 2 van de 5 pagina's
In winkelwagenResidential Electrician Exam #1 
 
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only - A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of ot...
1x verkocht
Michigan Journeyman test | 2023/24 questions and answers 
 
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - 4 
Thermal insulation shall not be installed within _...
Voorbeeld 1 van de 4 pagina's
In winkelwagenMichigan Journeyman test | 2023/24 questions and answers 
 
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - 4 
Thermal insulation shall not be installed within _...
NEC 2011 Journeyman Electrical Exam Study Guide (Michigan) 
 
Grounding and Bonding: 
 
Where outside, aluminum or copper-clad aluminum grounding electrode conductors shall not be terminated within ____in. of Earth. 
 
A. 12 in. 
B. 18 in. 
C. 24 in. 
D. 36 in. - B. 18 in. 
 
250.64(A) 
Temporary ...
Voorbeeld 2 van de 11 pagina's
In winkelwagenNEC 2011 Journeyman Electrical Exam Study Guide (Michigan) 
 
Grounding and Bonding: 
 
Where outside, aluminum or copper-clad aluminum grounding electrode conductors shall not be terminated within ____in. of Earth. 
 
A. 12 in. 
B. 18 in. 
C. 24 in. 
D. 36 in. - B. 18 in. 
 
250.64(A) 
Temporary ...
Journeyman Electrician Exam 3 
 
Where a water pipe passes over an indoor motor control center, leak protection apparatus shall have a MINIMUM clearance of _____. 
 
a) 6 feet to the protection apparatus 
b) 6 feet to the water pipe 
c) 6 1⁄2 feet to the protection apparatus 
d) 6 1⁄2 feet to th...
Voorbeeld 2 van de 5 pagina's
In winkelwagenJourneyman Electrician Exam 3 
 
Where a water pipe passes over an indoor motor control center, leak protection apparatus shall have a MINIMUM clearance of _____. 
 
a) 6 feet to the protection apparatus 
b) 6 feet to the water pipe 
c) 6 1⁄2 feet to the protection apparatus 
d) 6 1⁄2 feet to th...
PSI Journeyman Online Practice Test | 100 Q/A | 2023/24 
 
A fitting is a part of a wiring system that is intended primarily to perform which type of function? - mechanical 
When the disconnecting means of a transformer is located remotely it must be? - lockable 
If installed and routed on the out...
Voorbeeld 2 van de 6 pagina's
In winkelwagenPSI Journeyman Online Practice Test | 100 Q/A | 2023/24 
 
A fitting is a part of a wiring system that is intended primarily to perform which type of function? - mechanical 
When the disconnecting means of a transformer is located remotely it must be? - lockable 
If installed and routed on the out...
Journeyman Electrical Closed Book Exam #1 
 
An advantage of an electromagnent over a permanent magnent is that ____. - An electromagnent can be switched on and off. 
An excellent diffuser surface is one that ____. - Scatters light uniformly in all directions. 
Light is converted into electricity ...
Voorbeeld 1 van de 2 pagina's
In winkelwagenJourneyman Electrical Closed Book Exam #1 
 
An advantage of an electromagnent over a permanent magnent is that ____. - An electromagnent can be switched on and off. 
An excellent diffuser surface is one that ____. - Scatters light uniformly in all directions. 
Light is converted into electricity ...
Toledo journeyman test| with complete solution 
 
Transformers are rated in - kva 
a conductor intended solely for grounding purposes shall be a bare conductor or be color coded - green with one or more yellow stripes 
the lighting unit load for a store is listed as _______ VA per sq. ft - 3 
lis...
Voorbeeld 2 van de 10 pagina's
In winkelwagenToledo journeyman test| with complete solution 
 
Transformers are rated in - kva 
a conductor intended solely for grounding purposes shall be a bare conductor or be color coded - green with one or more yellow stripes 
the lighting unit load for a store is listed as _______ VA per sq. ft - 3 
lis...
Journeyman Electrician | questions and answers 2023/24 
 
For other than one-and two-family dwellings, when building a new electrical service, at least one (1) 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be located within at LEAST _____ of the electrical service equipment?...
Voorbeeld 2 van de 7 pagina's
In winkelwagenJourneyman Electrician | questions and answers 2023/24 
 
For other than one-and two-family dwellings, when building a new electrical service, at least one (1) 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be located within at LEAST _____ of the electrical service equipment?...
Washington State Journeyman Study Guide 
 
Who can grant a variance for electrical work? - the department or city that has inspection jurisdiction 
Residential buildings wired in Canada, then moved into Washington, must be inspected to ensure compliance with minimum safety requirements. Which is no...
Voorbeeld 2 van de 8 pagina's
In winkelwagenWashington State Journeyman Study Guide 
 
Who can grant a variance for electrical work? - the department or city that has inspection jurisdiction 
Residential buildings wired in Canada, then moved into Washington, must be inspected to ensure compliance with minimum safety requirements. Which is no...
Maine State Journeyman Exam up to 15gph | questions and answers 
 
How many apprentices can a journeyman directly supervise? - 2 
When performing any service work on a customers heating system the licensee must notify the homeowner of? - Efficiency and code violations 
Can a licensed journeyman pe...
Voorbeeld 1 van de 4 pagina's
In winkelwagenMaine State Journeyman Exam up to 15gph | questions and answers 
 
How many apprentices can a journeyman directly supervise? - 2 
When performing any service work on a customers heating system the licensee must notify the homeowner of? - Efficiency and code violations 
Can a licensed journeyman pe...
Journeyman lineman 
 
What fahrenheit tempature would a transformer have to be 55% centigrade above ambrient of 98* F? - 55x1.8=99 + 32 = 131*F 
131 + 98= 229* 
A conductor is pulled to what tension? - 50% 
To dead end three 2/0 HD conductors which have a breaking strength of 5,927 lbs each 
A. Ho...
Voorbeeld 1 van de 3 pagina's
In winkelwagenJourneyman lineman 
 
What fahrenheit tempature would a transformer have to be 55% centigrade above ambrient of 98* F? - 55x1.8=99 + 32 = 131*F 
131 + 98= 229* 
A conductor is pulled to what tension? - 50% 
To dead end three 2/0 HD conductors which have a breaking strength of 5,927 lbs each 
A. Ho...
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper STUVATE. Stuvia faciliteert de betaling aan de verkoper.
Nee, je koopt alleen deze samenvatting voor €14,70. Je zit daarna nergens aan vast.
4,6 sterren op Google & Trustpilot (+1000 reviews)
Afgelopen 30 dagen zijn er 93705 samenvattingen verkocht
Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen