Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about ? On this page you'll find 42 study documents about .

All 42 results

Sort by

ACI Concrete Field Testing Technician  Grade I Practice Exam Questions and  Answers 100% Verified
  • ACI Concrete Field Testing Technician Grade I Practice Exam Questions and Answers 100% Verified

  • Exam (elaborations) • 5 pages • 2024
  • ACI Concrete Field Testing Technician Grade I Practice Exam Questions and Answers 100% Verified The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - CORRECT ANSWER-77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - CORRECT ANSWER-0.5 C / +-1F / 0-50 Decrees C The tem...
    (0)
  • $15.49
  • + learn more
ACI Concrete Field Testing Technician- Grade I Exam Questions And Answers 100% Verified
  • ACI Concrete Field Testing Technician- Grade I Exam Questions And Answers 100% Verified

  • Exam (elaborations) • 10 pages • 2024
  • ACI Concrete Field Testing Technician- Grade I Exam Questions And Answers 100% Verified The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. - answer3 in. [75 mm] The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. - answer1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] The temperature ...
    (0)
  • $12.49
  • + learn more
ACI Concrete Field Testing Technician - Grade I Exam Questions And Answers 100% Verified
  • ACI Concrete Field Testing Technician - Grade I Exam Questions And Answers 100% Verified

  • Exam (elaborations) • 5 pages • 2024
  • ACI Concrete Field Testing Technician - Grade I Exam Questions And Answers 100% Verified The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - answer77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - answer0.5 C / +-1F / 0-50 Decrees C The temp. measuring device shall be ve...
    (0)
  • $10.49
  • + learn more
ACI Concrete Field-Testing Technician - Grade I | 100% Correct Answers | Verified | Latest 2024 Version
  • ACI Concrete Field-Testing Technician - Grade I | 100% Correct Answers | Verified | Latest 2024 Version

  • Exam (elaborations) • 6 pages • 2024
  • The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - 77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - 0.5 C / +-1F / 0-50 Decrees C The temp. measuring device shall be verified __, or whenever there is a question of __. - Annually / accuracy The temp of concrete may be mea...
    (0)
  • $12.99
  • + learn more
ACI Concrete Field-Testing Technician - Grade 1 Exam Review | 100% Correct Answers | Verified | Latest 2024 Version
  • ACI Concrete Field-Testing Technician - Grade 1 Exam Review | 100% Correct Answers | Verified | Latest 2024 Version

  • Exam (elaborations) • 43 pages • 2024
  • Q1. Start molding specimens for strength tests within 30 minutes after fabricating the composite sample. A. True B. False - B. False ASTM C172 -Para (4.1.2) - Start molding. specimens for strength tests within 15 min after fabricating the composite sample. Q2. The maximum allowable time between obtaining the first and last portions of the composite sample may not exceed 5 minutes. A. True B. False - B. False ASTM C172 - Para (4.1)- The elapsed time shall not exceed 15 min. between obta...
    (0)
  • $15.99
  • + learn more
ACI Concrete Field-Testing Technician- Grade I Questions | 100% Correct Answers | Verified | Latest 2024 Version
  • ACI Concrete Field-Testing Technician- Grade I Questions | 100% Correct Answers | Verified | Latest 2024 Version

  • Exam (elaborations) • 14 pages • 2024
  • Section 1: Temperature of Freshly Mixed Hydraulic-Cement Concrete - C1064 The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of _____ into the freshly mixed concrete. - 3 inches The temperature measuring device shall be capable of accurately measuring temperature of freshly mixed concrete to _____, throughout a range of _____. - +/- 1 °F 30 °F to 120 °F The temperature measuring device shall be verified _____, or whenever there is a que...
    (0)
  • $11.49
  • + learn more
ACI Concrete Field-Testing Technician- Grade I Study Guide | 100% Correct Answers | Verified | Latest 2024 Version
  • ACI Concrete Field-Testing Technician- Grade I Study Guide | 100% Correct Answers | Verified | Latest 2024 Version

  • Exam (elaborations) • 14 pages • 2024
  • The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. - 3 in. [75 mm] The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. - 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. - Annually, accu...
    (0)
  • $11.49
  • + learn more
ACI Concrete Field-Testing Technician - Grade I | 100% Correct Answers | Verified | Latest 2024 Version
  • ACI Concrete Field-Testing Technician - Grade I | 100% Correct Answers | Verified | Latest 2024 Version

  • Exam (elaborations) • 6 pages • 2024
  • Available in package deal
  • The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - 77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - 0.5 C / +-1F / 0-50 Decrees C The temp. measuring device shall be verified __, or whenever there is a question of __. - Annually / accuracy The temp of concrete may be mea...
    (0)
  • $8.49
  • + learn more
ACI Concrete Field-Testing Technician- Grade I Questions | 100% Correct Answers | Verified | Latest 2024 Version
  • ACI Concrete Field-Testing Technician- Grade I Questions | 100% Correct Answers | Verified | Latest 2024 Version

  • Exam (elaborations) • 14 pages • 2024
  • Available in package deal
  • Section 1: Temperature of Freshly Mixed Hydraulic-Cement Concrete - C1064 The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of _____ into the freshly mixed concrete. - 3 inches The temperature measuring device shall be capable of accurately measuring temperature of freshly mixed concrete to _____, throughout a range of _____. - +/- 1 °F 30 °F to 120 °F The temperature measuring device shall be verified _____, or whenever there is a que...
    (0)
  • $10.49
  • + learn more