Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about ? On this page you'll find 524 study documents about .
All 524 results
Sort by
-
BICSI TECHNICIAN EXAM LATEST QUESTIONS WITH 100% CORRECT ANSWERS | 2024 UPDATE
- Exam (elaborations) • 4 pages • 2024
- Available in package deal
-
- $10.49
- 2x sold
- + learn more
BICSI TECHNICIAN EXAM LATEST QUESTIONS WITH 100% 
CORRECT ANSWERS | 2024 UPDATE 
L Rating - Answer ️️ -A firestops ability to provide a smoke stop. (air leakage rate) 
To avoid damaging cable jacket, how often must you securely fasten electrical nonmetallic 
tubing (ENT) - Answer ️️ -3 Feet so it does not damage the cable 
What is the minimum dedicated power requirement of a telecommunications enclosure - Answer ️️ 
-120 V ac/20 
The clearance behind the PBB when mounted, should be n...
-
BICSI TECHNICIAN EXAM LATEST QUESTIONS WITH 100% CORRECT ANSWERS | 2024 UPDATE
- Exam (elaborations) • 4 pages • 2024 Popular
- Available in package deal
-
- $10.49
- 1x sold
- + learn more
BICSI TECHNICIAN EXAM LATEST QUESTIONS WITH 100% 
CORRECT ANSWERS | 2024 UPDATE 
L Rating - Answer ️️ -A firestops ability to provide a smoke stop. (air leakage rate) 
To avoid damaging cable jacket, how often must you securely fasten electrical nonmetallic 
tubing (ENT) - Answer ️️ -3 Feet so it does not damage the cable 
What is the minimum dedicated power requirement of a telecommunications enclosure - Answer ️️ 
-120 V ac/20 
The clearance behind the PBB when mounted, should be n...
-
BICSI Technician- Netcom - Chapter 1 Exam Questions With Verified Answers
- Exam (elaborations) • 12 pages • 2024
-
- $12.49
- + learn more
BICSI Technician- Netcom - Chapter 1 Exam 
Questions With Verified Answers 
Three transmission methods are - answerSymplex, half duplex, full duplex 
The choice of a specific transport medium is influenced by 5 economics and technical 
considerations such as the: - answerPhysical construction, type of services, topology and size 
of the network, transmission path distance, transmission performance characteristics of the 
cabling. 
Twisted pair cable is called balanced cable because: - answerThe ...
-
BICSI Installer 1 Exam Questions With Verified Answers
- Exam (elaborations) • 12 pages • 2024
-
- $12.49
- + learn more
BICSI Installer 1 Exam Questions With 
Verified Answers 
25-pair color code - answerWhite - Blue, orange, green, brown, slate 
Red - Blue, orange, green, brown, slate 
Black - Blue, orange, green, brown, slate 
Yellow - Blue, orange, green, brown, slate 
Violet - Blue, orange, green, brown, slate 
Fiber color code - answerBlue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, 
Violet, Rose, Aqua 
NVP - answerNominal Velocity of Propagation 
Insertion loss - answerThe difference in the amo...
-
BICSI Practice Test-RETAKE Exam Questions With Verified Answers
- Exam (elaborations) • 8 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
BICSI Practice Test-RETAKE Exam 
Questions With Verified Answers 
The 2 main considerations concerning the existing cabling are? - answerGrandfathered 
system 
Abandoned cable 11-25 
The type of cutover where cross-connects are relocated one pair after another until completed is 
called a - answerrolling cut 11-28 
Which practice involves moving the customer to a temporary office space until their section of 
the retrofit is completed and then moving them back to their recabled office space? - 
...
And that's how you make extra money
-
BICSI Installer 2 Copper Study Exam Questions With 100% Correct Answers
- Exam (elaborations) • 4 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
BICSI Installer 2 Copper Study Exam 
Questions With 100% Correct Answers 
There are four classes of administration of Structure cabling system (SCS) - answerClass 1 
single ER equipment room 
Class 2 multiple 
telecommunication spaces 
Class 3 multiple buildings on campus 
Class 4 multiple sites 
Endothermic - answerAbility to absorb heat 
3 basic types of crosstalk of interest for balaced twisted pair - answerNear End (NEXT) 
Attenuation to crosstalk far end (ACRF) 
Alien crosstalk 
intumescent...
-
BICSI RTPM Exam Questions With 100% Correct Answers
- Exam (elaborations) • 33 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
BICSI RTPM Exam Questions With 100% 
Correct Answers 
design and implementation/installation - answerTelecommunications project management 
(TPM) typically consists of two distinct processes: 
Design PM Tasks - answerReview expression of interest for client 
Perform a user needs analysis 
Perform site surveys and meet with client 
Generate preliminary design submittals 
Respond to/incorporate client comments 
Prepare final bid documents/RFP and engineer's cost estimate 
Issue final RFP package ...
-
BICSI Technician HW Exam Questions And Answers (Verified And Updated)
- Exam (elaborations) • 3 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
BICSI Technician HW Exam Questions And 
Answers (Verified And Updated) 
The function of which type of cable is to provide interconnections between equipment rooms and 
telecommunications rooms? - answerBackbone cable 
The main components of backbone cabling are cabling pathways, cables, miscellaneous support 
facilities and which of the following? - answerConnection hardware 
What is the maximum length of a patch cord? - answer16.4' 
You are installing horizontal structured cabling in an open o...
-
BICSI Installer 2: Fiber Module Exam Questions With 100% Correct Answers
- Exam (elaborations) • 8 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
BICSI Installer 2: Fiber Module Exam 
Questions With 100% Correct Answers 
Code - answerAddresses the safety of persons, property and the environment associated with 
the ITS cabling Installation 
NEC - answerNational electric code 
Frequency conversion chart - answerOne thousand hertz = 1KHz 
One million Kilohertz = 1 MHz 
One billion Megahertz = 1 GHz 
NFPA - answerNational Fire protection association 
AHJ - answerAuthorities having jurisdiction 
TIA/EIA - answer- Telecommunications Industry a...
-
Systems Verification BICSI Final Exam Questions And Answers (Verified And Updated)
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Systems Verification BICSI Final Exam 
Questions And Answers (Verified And 
Updated) 
Cross Connects, Backbone Cabling, and Administration - answerAdministration systems 
include requirements for; identifiers - that serve to locate the element record and administration 
scheme such as the standards found in ANSI/TIA 606-B, records - which can be paper based, 
spreadsheets, database programs, or computer programs specially designed for that purpose, and 
labeling - with a variety of methods to di...
-
Bicsi Study Questions With Verified Answers
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Bicsi Study Questions With Verified 
Answers 
Which of the following is a property of an electromagnetic field built around a conductor that 
opposes any changes in current flow in a circuit? - answerImpedance 
_____________ is obtained by repeat positive actions on a daily basis - 
answerProfessionalism 
Which of the following markings is used for nonconductive optical fiber general-purpose cables? 
- answerOFNG 
The installer must take responsibility to know, understand, and _______ all aspect...
-
Bicsi Installer 2, Copper, Chapter 1, Balanced Twisted Pare Cable Exam Questions And Answers (Updated And Verified)
- Exam (elaborations) • 9 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
Bicsi Installer 2, Copper, Chapter 1, 
Balanced Twisted Pare Cable Exam 
Questions And Answers (Updated And 
Verified) 
Balanced twisted-pair cables have a nominal characteristic impedance of - answer100 ohms 
at 100 MHz 
Insulation - answerCopper wires must be physically separated 
UTP - answerunshielded twisted-pair 
screened/shielded cabling offers - answera higher immunity to EMI and may be used in areas 
susceptible to EMI, possibly eliminating the need for metallic conduit in some environm...
Did you know that on average a seller on Stuvia earns $82 per month selling study resources? Hmm, hint, hint. Discover all about earning on Stuvia